top of page
Interzone-505.jpg

Interzone 505

(Glass Flake Epoxy)

▣ PRODUCT

 

  • Interzone 505 (Glass Flake Epoxy)

 

▣ PRODUCT DESCRIPTION

 

  • A high solids, low VOC, high build epoxy primer/intermediate or finish coat, reinforced with chemically resistant high aspect ratio glass flake for enhanced durability and corrosion resistance.

 

▣ INTENDED USES

 

  • For the protection of steelwork in all corrosive environments including splashzone areas on offshore structures, underdeck, decks and above water areas, pilings, pulp and paper mills, bridges and chemical plants.

  • To provide excellent long term, anti-corrosive and anti-abrasion protection in both new construction and maintenance situations.

  • As part of a non-slip deck system in conjunction with appropriate aggregate.

 

▣  PRACTICAL INFORMATION FOR INTERZONE 505

  • Color : Limited color range

  • Volume Solids : 90%

  • Typical Thickness : 12-20 mils (300-500 microns) dry equivalent to 13.3-22.2 mils (333-556 microns) wet

  • Method of Application : Airless Spray, Air Spray, Brush, Roller

▣ Drying Time

  • Base Temperature : 77°F (25°C)

  • Touch Dry : 3 hours

  • Hard Dry : 6 hours

  • Overcoating Interval with recommended topcoats

       - ​Minimum : 6 hours

       - Maximum : 4 days

▣ SURFACE PREPARATION

 

  • Oil or grease should be removed in accordance with SSPC-SP1 solvent cleaning.

▣ APPLICATION

  • Mix Ratio : 1.5 part(s) : 1 part(s) by volume

​​​

  • Airless Spray - Recommended

      : Tip Range 0.53-0.79 mm (21-31 thou)
      : Total output fluid pressure at spray tip not less than

        211 kg/cm² (3000 p.s.i.)

​​​

  • Air Spray (Pressure Pot) - Recommended

      : Gun DeVilbiss MBC or JGA
      : Air Cap 62
      : Fluid Tip AC

​​​

  • Brush : Suitable - Small areas only

 

  • Roller : Suitable - Small areas only

  • Thinner : International GTA220

                     (International GTA415)

 

▣ SYSTEMS COMPATIBILITY

 

  • Interzone 505 can be applied directly to blasted steel but can also be used over the following primers for underwater systems:

        Intergard 269         Interline 982

 

  • When used in aggressive exterior exposure environments the following primers are recommended for Interzone 505:

        Intercure 200         Interzinc 52

        Intergard 251         Interzinc 315

        Interzinc 22 (mist coat or tie coat recommended)

  • The following topcoats are recommended for Interzone 505:

        Interfine 629HS      Interthane 990

▣ STORAGE

 

  • ​12 months minimum at 25°C (77°F).

  • Subject to re-inspection thereafter. Store in dry, shaded conditions away from sources of heat and ignition.

Product Data Sheet (TDS)

English

Russian

악조노벨&엠디 로고 재수정.png
  • MD Industry
  • MD Industry

E-mail  :    md@mduzb.com

TEL  : +998-95-145-1117

070-7001-0477

Visitor
bottom of page